There have been 47 defect investigations conducted for 19 Saturn models. The Saturn model with the most defect investigations conducted is Saturn LS with 10 defect investigations.
Latest Defect Investigations of Saturn Vehicles|
This investigation was opened on May. 20, 2011.
It was closed on Nov. 22, 2011.
Gm advised that the shift cable's protective outer conduit (jacket) deteriorates with time and use. Variables that affect jacket life include installation variability (routing, etc), environmental and temperature effects, and material quality.
Vehicles covered by this investigations include the 2007 Saturn Aura. See investigation details » |
|
This investigation was opened on Dec. 15, 2010.
It was closed on Oct. 5, 2011.
Odi has received 846 complaints and gm identified 3,489 reports alleging sudden loss of steering power assist in model year (my) 2004 through 2007 Saturn ion vehicles manufactured and sold by general motors corporation (gm).
Vehicles covered by this investigations include the 2004 Saturn ION, the 2005 Saturn ION, the 2006 Saturn ION, the 2007 Saturn ION. ... See investigation details » |
|
This investigation was opened on May. 21, 2009.
It was closed on Oct. 27, 2009.
The office of defects investigation opened this investigation based on nine vehicle owner questionnaire (voq) reports alleging gasoline leakage from the in-tank fuel pump assembly. Some complainants reported leaks from the fuel pump "nipple" (I. E.
Vehicles covered by this investigations include the 2002 Saturn LS. See investigation details » |
|
This investigation was opened on Mar. 10, 2009.
It was closed on Jul. 2, 2009.
This investigation resulted in
a vehicle safety recall. By letter dated June 23, 2009, general motors notified the agency that it will conduct a safety recall (NHTSA recall number 09v233) to replace the outside door handles on certain model year 2008 Saturn vue vehicles. Vehicles covered by this investigations include the 2008 Saturn VUE, the 2008 Saturn Vue Hybrid. See investigation details » |
|
This investigation was opened on Oct. 16, 2008.
It was closed on Apr. 8, 2009.
On may 22, 2008, theoffice of defects investigation (odi) was petitioned by the north carolina consumers council (nccc) to broaden the scope of safety recall 07v-519, which was conducted by general motors corporation (gm) for model year (my) 2001 Saturn l-series vehicles equipped with the l61 2.
Vehicles covered by this investigations include the 2000 Saturn LS, the 2001 Saturn LS, the 2002 Saturn LS. See investigation details » |