NHTSA Campaign Id 04V068000; Date: Feb. 18, 2004
Due to such a startling event, the individual refueling the vehicle could remove the fuel nozzle at precisely the moment of the detonation without first stopping the fueling process. In such a circumstance, fuel escaping outside of the fuel tank may ignite, resulting in a fire.
Recalled Vehicles:2003 Porsche Cayenne S; 2003 Porsche Cayenne Turbo
Component: Fuel System, Gasoline:storage:tank Assembly:filler Pipe And Cap
Manufactured by: Porsche Cars North America, Inc.
Affected Units:: 35
Recall Summary:On certain sport utility vehicles, if the ground connection between the spiral ring of the tank filler neck and the connecting pipe to the fuel tank is inadequate, the flow of fuel during refueling can create an electrostatic charge, which could discharge and spark. This spark could ignite fuel vapors in the area outside the tank filler neck that could lead to a muffled detonation.
How to Fix:Dealers will inspect the ground connection and, if necessary, corrected. Owner notification began on March 29, 2004. Owners should contact Porsche at 1-800-545-8039.
Recall Notes:Customers can also contact the national highway traffic safety administration's auto safety hotline at 1-888-dash-2-dot (1-888-327-4236).
Date Owners notified by Manufacturer: Mar 29, 2004
Also see: