All Bulletins » Gillig » Low Floor

Gillig Low Floor Technical Service Bulletins

Technical Service Bulletins of Gillig Low Floor Model Years


Latest Technical Service Bulletins of Gillig Low Floor

2018 Gillig Low Floor electrical system TSB (Bulletin FS-2021-001)

Bulletin Date: Feb. 8, 2021
Component: Electrical system
Bulletin Summary: Certain buses built with kissling floor mounted toe switches may be susceptible to premature failure.
Vehicles covered in this TSB:
2018 Gillig Low Floor, 2019 Gillig Low Floor.

2016 Gillig Low Floor electrical system:wiring:fuses and circuit breakers TSB (Bulletin FS-2020-04)

Bulletin Date: Jul. 2, 2020
Component: Electrical system:wiring:fuses and circuit breakers
Bulletin Summary: During the review of the coolant sensor circuit in some buses, it was determined that the 10 amp circuit breaker currently utilized in this circuit should be replaced with a 4 amp circuit breaker.
Vehicles covered in this TSB:
2016 Gillig Low Floor.

2013 Gillig Low Floor electrical system TSB (Bulletin FS-2019-03)

Bulletin Date: May. 28, 2019
Component: Electrical system
Bulletin Summary: After a review of the fuse selection in some of your 2013 through 2015 hybrid buses, gillig determined that the fuses in the battery fuse box need to be changed.
Vehicles covered in this TSB:
2013 Gillig Low Floor, 2014 Gillig Low Floor, 2015 Gillig Low Floor.