All Investigations » Investigation RQ06006

  Defect Investigation of Instrument Panel Fires

Investigation of Instrument Panel Fires

Subject: Instrument panel fires
Components covered:
  • Electrical system: instrument cluster/panel
  • Instrument panel
  • Interior/under dash wiring
Investigations Summary: This investigation was opened on May. 5, 2006. It was closed on Aug. 28, 2006. This investigation originated from complaints received by the agency reporting instrument panel (ip) fires on vehicles that were recalled(recall 03v528) by daimlerchrysler (dcc) to correct a defect that caused ip fires. The recall corrected a defect caused by a certain capacitor on the ip printed circuit board (pcb) that could crack and overheat. The fire could occur without warning while the vehicle is parked or in use. The recall remedy was to remove the capacitor from the ip. Ips used for vehicles produced after the recall (December 2003) did not contain the capacitor. Odi has also received reports of fires in vehicles produced after the recall, which do not have the defective capacitor. Dcc and its supplier for the ip have identified a different location on the pcb that may overheat. This investigation has been upgraded to an engineering analysis (ea06-015) to further study this issue.
Vehicles Affected by this investigation:
  • 2004 Dodge Durango

    Other investigations related to Dodge vehicles

  Defect investigation of seat belt retraction

  Defect investigation of powered vehicle rollaway

  Defect investigation of totally integrated power module failure

  Defect investigation of engine stall after refueling

  Defect investigation of rear differential failure