Blower Problems of Ford Taurus - part 1

Ford Taurus owners have reported 136 problems related to blower (under the visibility category). The most recently reported issues are listed below. Also please check out the statistics and reliability analysis of Ford Taurus based on all problems reported for the Taurus.

1 Blower problem of the 2007 Ford Taurus

Failure Date: 03/11/2015

The contact owns a 2007 Ford Taurus. Whenever it rained, the contact noticed a puddle of water on the passenger seat. In addition, the heater blower motor was leaking. There were no prior warnings. The vehicle was not diagnosed nor repaired. The failure mileage was 55,000. The VIN was not provided.

See all problems of the 2007 Ford Taurus 🔎.

2 Blower problem of the 2003 Ford Taurus

Failure Date: 07/08/2014

The contact owns a 2003 Ford Taurus. While driving at any speed, the blower motor emitted smoke from under the dashboard on the passenger side of the vehicle. The failure recurred three times. The vehicle was taken to an independent mechanic where it was diagnosed that the resister blower motor was getting damaged with water from the crow and under the air cabin filter where the installation of the cabin air filter. The technician informed the contact that the vehicle need to be taken to a dealer to have the installation replaced. The vehicle was repaired twice; however, the failure recurred. The manufacturer was notified of the failure. The approximate failure mileage was 132,000.

See all problems of the 2003 Ford Taurus 🔎.

3 Blower problem of the 2001 Ford Taurus

Failure Date: 10/13/2013

The contact owns a 2001 Ford Taurus. The contact stated while driving 35 mph, he noticed that the passenger side floor board was soaked. The vehicle was taken to an independent mechanic who stated that the blower motor was defective and the sealant needed to replaced. The manufacturer was made aware of the failure. The vehicle was not repaired. The failure mileage was 200,000 and the current mileage was 205,000.

See all problems of the 2001 Ford Taurus 🔎.

4 Blower problem of the 2003 Ford Taurus

Failure Date: 12/17/2012

The heater blower motor has stopped working in my vehicle. I have had it replaced once and it worked for about 2 months before failing again. Ford has issues a bulletin on this issue and it is a known problem, but they will not fix the problem if the car is no longer under warranty.

5 Blower problem of the 2003 Ford Taurus

Failure Date: 11/23/2011

Water leak on passenger floor,shorted blower motor.

6 Blower problem of the 2003 Ford Taurus

Failure Date: 10/24/2011

The contact owns a 2003 Ford Taurus. The contact stated that the defroster was inoperable. The vehicle was taken to an independent mechanic where they advised him that the blower motor had failed and needed to be replaced. The vehicle was not repaired. The manufacturer was contacted and they offered no assistance. The failure and the current mileages were approximately 58,000.

7 Blower problem of the 2005 Ford Taurus

Failure Date: 05/09/2011

I have a 2005 Ford Taurus. Whenever there is moderate to heavy rainfall, water leaks into the passenger side under the dash, soaking the floor and the blower motor will not work. While driving the windshield fogs over and I cannot get the blower to turn on, causing visibility issues while driving on the road. This is happening to a lot of people, this should be investigated and a recall issued.

See all problems of the 2005 Ford Taurus 🔎.

8 Blower problem of the 2003 Ford Taurus

Failure Date: 03/01/2011

2003 Ford Taurus sec wagon with a leaky windshield. Water got into my a/c blower fan housing and shorted out the a/c blower fan, caused the blower fan to fail, the automatic temperature resister switch and the 40 amp fuse in the same system due to water entering into the car from the windshield and cowl design flaw. The result is a loss of defroster and anti-fog capability resulting in a severe loss of visability due to a loss of said capability and/or functionality.

9 Blower problem of the 2003 Ford Taurus

Failure Date: 02/20/2011

Purchased 2003 Ford Taurus with 49k miles 8 months ago. Blower motor and resistor have failed twice. Water is coming into the blower housing through the air intake. Recent failure at 60k happened in cold weather while on the road, causing fan to stop working and windsheild rapidly fogged over, making it impossible to see. Failure was accompanied by strong electrical burning smell.

10 Blower problem of the 2003 Ford Taurus

Failure Date: 12/20/2010

The contact owns a 2003 Ford Taurus. The contact stated that the heater blower had malfunctioned. The contact took the vehicle to the dealer to have a the blower resistor replaced yet the repair did not correct the failure. The vehicle was taken back to the dealer where the dealer discovered water damage around the heater blower. The dealer created a shield around and replaced the heater blower. The failure mileage was 49,152.

11 Blower problem of the 2003 Ford Taurus

Failure Date: 06/03/2010

The contact owns a 2003 Ford Taurus. The contact stated that whenever the air conditioner was activated, the front passenger side floorboard would become wet. The vehicle was taken to an authorized dealer where the contact was informed that motor blower would need to be replaced. There were no prior warnings of the failure. The failure mileage was 84,000 and the current mileage was 86,000.

12 Blower problem of the 2007 Ford Taurus

Failure Date: 06/03/2010

Failure of the heater / ac / defroster blower motor due to water leakage through the firewall cowling. This problem has been known to Ford since at least 2003, yet they have not implemented their own TSB 04-15-3 on the production line as recently as 2007. Ford refuses to issue a recall claiming that there is no safety issue involved even though failure of the blower could cause reduced visibility in inclement weather due to failure of the defroster or defogger. There is also a strong possibility of fire should the blower short or seize due to water and rust build-up in the blower motor.

13 Blower problem of the 2003 Ford Taurus

Failure Date: 06/02/2010

I have just purchased a 03 Taurus which leaked water onto the passenger floor board also causing my ac blower motor to short out. When it is raining, humid or later when it gets cold there will be no way to keep the windshield clear of interior condensation or frost. This will make driving dangerous if caught in a storm. I have been able to get Ford to act even though a related recall existed under 03v087000. I have found many others with this problem. I have read the descriptions related to recall number 03v087000 and Ford TSB 04-15-3. I also see there is an existing complaint number to NHTSA: 10184014. The water leaks during storms regardless of whether the car is driving or sitting still. The fan first would only run on high speed and now won't run at all. This is an known design defect and I am frustrated that I can't get it remedied by Ford.

14 Blower problem of the 2003 Ford Taurus

Failure Date: 01/08/2010

My blower in my 2003 Ford Taurus has been intermittently failing for a month or so. On Friday Jan. 8 it quit and will not go. The heat is fine and trickles out, but the blower will not come on at all. It was fine at 8:30pm when I picked a friend up at the airport, but was dead at 10:30pm when I picked up my granddaughter at a friends house. It appears that there has been water in the housing that has shorted out the motor. I understand that Ford knows this is a problem with these cars but is reluctant to do a recall to fix it.

15 Blower problem of the 2003 Ford Taurus

Failure Date: 01/01/2010

The contact owns a 2003 Ford Taurus. The contact stated that both the blower motor and the interior lights experienced failures. As a result, hot air would not blow from the vents and the windshield could not be defrosted. The interior lights illuminated constantly and drained the battery prematurely. The dealer reprogrammed the electrical system computer and corrected the interior light failure. The blower motor failure was not corrected. The failure mileage was 82,555 and the current mileage 85,754. Updated 03/05/lj updated 03/06/12.

16 Blower problem of the 2003 Ford Taurus

Failure Date: 12/15/2009

Water in the blower case or on the passenger side floor, and the blower motor only works on high speed. Contacted dealer and was told that it was a service bulletin. Asked if it was covered under recall number 03v087000 and was told no.

17 Blower problem of the 2002 Ford Taurus

Failure Date: 08/01/2009

I own a 2002 Ford Taurus and understand many people have had this same issue. My a/c blower motor stopped working and was filled with water with traces of rust. I replaced the blower control switch, the blower resistor board, and removed and rebuilt the blower motor. The auto parts store I bought the replacement components from (directly across the street from the Ford dealer) tells me this is a common occurrence.

See all problems of the 2002 Ford Taurus 🔎.

18 Blower problem of the 2004 Ford Taurus

Failure Date: 06/01/2009

Filing complaint against Ford motor company defective engineering design of the blower motor mounting where rain and dampness gets into the blower destroying not only the blower motor but also the resistor. Replacement of these no longer functioning parts along with a rain kit to prevent future water damage was estimated at $583. 00 plus tax. Upon calling Ford motor company was told that they were aware of complaints of this problem posted on the internet but not enough people have called Ford to complain and therefore it was, basically, my problem as it was not a safety issue. This is indeed a safety issue when there is now absolutely no ventilation system in this car whatsoever due to the defective design and the parts going out. Safety concern? you bet when you have no air ventilation system in your car are pushing close to 60 years old and drive in humid chicagoland. Ford motor company will have a real safety issue when I pass out or die while driving in there defective non-working - no ventilated car!.

See all problems of the 2004 Ford Taurus 🔎.

19 Blower problem of the 2003 Ford Taurus

Failure Date: 05/25/2009

I just discovered water in my blower motor on my 2003 Ford Taurus. Recently my blower stopped working all together and it will not work at all now. I am currently going to replace the blower motor resistor and see if this repairs the problem. It seems several people have had this issue.

20 Blower problem of the 2003 Ford Taurus

Failure Date: 05/14/2009

I own a 2003 Ford Taurus that the blower is bad and apparently due to water damage through the vent area, I see where on the internet this may be a recurring issue that Ford has not issued a recall on. What course of action should I take to get this resolved so I don't have to continue to buy blower motors. The car is very reliable other than this.

21 Blower problem of the 1999 Ford Taurus

Failure Date: 05/03/2009

The contact owns a 1999 Ford Taurus. The air conditioner blower motor has a shortage and the passenger side floor was always wet due to a leak. The dealer has not diagnosed the failure and the manufacturer has not been notified. The failure mileage was 199,000.

See all problems of the 1999 Ford Taurus 🔎.

22 Blower problem of the 2003 Ford Taurus

Failure Date: 03/25/2009

2003 Ford Taurus. Fan blower motor (for heat and air system) failed due to cowl leak on passenger side of vehicle. Known issue for Ford. Can create hazardous driving conditions if failure occurs during rain or cold weather. (lack of heat or ac to clear windshield).

23 Blower problem of the 2003 Ford Taurus

Failure Date: 02/14/2009

In line with numerous other reports about the 2003 Ford Taurus, my blower motor and resister have failed due to a water leak on the front passenger side. As a consequence, I cannot defog the windshield while driving. The result lack of visibility is dangerous for my passengers and for nearby cars. Correcting this problem is not a simple matter of replacing the blower motor, but also requires a complicated repair of the causative leak. I request NHTSA to look into the numerous complaints like mine and work with Ford in issuing a recall for this issue.

24 Blower problem of the 2003 Ford Taurus

Failure Date: 01/29/2009

Heater blower failed to start.

25 Blower problem of the 2003 Ford Taurus

Failure Date: 01/13/2009

Rain water leaks onto the passenger side floorboard. This shorted out the heater/ac blower motor. Parts have not been replaced yet. Other complaints have been filed re:10184014. There is also a recall to replace the windshield which is the source of the leakage (03v087000).

26 Blower problem of the 2003 Ford Taurus

Failure Date: 01/10/2009

Due to improper sealing on passenger side of vehicle water leaks in and damages blower motor and blower motor resistor. This renders the defroster inoperable and therefore causes a dangerous visibility situation. This is a very common problem with the 2003 Ford Taurus.

27 Blower problem of the 2003 Ford Taurus

Failure Date: 12/28/2008

About 3 weeks ago, the heating/air conditioning on my 2003 Ford Taurus would only work on a high setting. A couple days later, it stopped working altogether. I took it into a mechanic, who replaced the blower motor and the resistor for over $400. Two weeks later, the blower motor went out again. I went to some random forum, and saw over one-hundred people upset because they own an 02 or 03 Taurus, and they have the same problem with their blowers. And there has never been a recall? I can't imagine how many Taurus owners are having this exact problem. All I know is that it is 20 degrees where I live right now and is going to be colder tomorrow. Not only is this uncomfortable, it is dangerous. It is clear that many others have complained about the same situation, so it's clear to me that nothing will be done. I just don't know what to do.

28 Blower problem of the 2002 Ford Taurus

Failure Date: 12/12/2008

Reference Ford TSB #04-15-3. I have a 2002 Ford Taurus ses with only 39,000 miles on the odometer and the blower motor had to be replaced because of water leaking from the bottom of the windshield into the blower motor. I was told by a local Ford dealer that there is a recall #03v087000 on this problem, but it expired in 2007, so I had no choice but to purchase a new motor for $133. 97, Ford part #1f1z-19805-aa. This is evidently an ongoing problem. The internet site I visited had 7 pages of complaints about this same situation. This becomes a safety issue because visibility is impaired due to the fact that now you do not have any window defrosters. I am writing this complaint mainly to see if Ford won't extend the above mentioned recall notice.

29 Blower problem of the 2000 Ford Taurus

Failure Date: 12/03/2008

First had fluid on passenger side floor,could not figure out where it came from then blower fan stopped working. Has been out for over a week. Window forms idc and can not even see out of it!.

See all problems of the 2000 Ford Taurus 🔎.

30 Blower problem of the 2003 Ford Taurus

Failure Date: 11/26/2008

Blower motor failure.

31 Blower problem of the 2003 Ford Taurus

Failure Date: 11/15/2008

One day my heater stopped blowing. I first checked the blower motor fuse, which was fine. During this process I found that the passenger side floorboard was soaking wet. After research online I found that a bunch of people have had this problem. The water apparently shorted out my blower motor so now I have no heat or air.

32 Blower problem of the 2002 Ford Taurus

Failure Date: 11/04/2008

With the cold michigan weather upon us, my heater blower is needed to provide removal of foggy/frosty windows for my children's safety and others. Ford has had complaints on the internet and dealers are aware of the problem, I spoke to my local dealer and they said this very common with the Ford Taurus as water enters the passenger floor board and shorts out the blower motor. They said this would be a $400. 00 repair.

33 Blower problem of the 2003 Ford Taurus

Failure Date: 10/24/2008

I have two vehicles and rarely drive my newer car in the rain. I took my newer car on vacation and was returning home when it started to rain. A couple days afterwards I was headed to work when my car started to fog up. I turned on the defrost fans and could barely hear the motor running. I turned to high where it ran for about 1 minute before completely failing. I figured that maybe my blower was failing. I searched on the internet and found that this is not an unusual problem with the 2003 Taurus and is a known problem (recall number 03v087000 and complaint 10184014). From what I am hearing, water is leaking into the blower unit and causing it to fail. The blower is in a completely useless due to this leak. I have called the dealership and they said it would be about $500 to fix. This is ridiculous for a design flaw in the manufacturing process. This is a safety issue and a design flaw on the vehicle. The blower was working during and up to the several hours of driving in the rain.

34 Blower problem of the 2003 Ford Taurus

Failure Date: 10/17/2008

I had the problem that my blower would only work on high speed. My mechanic knew right away that it was the blower motor resistor. So went to Ford and bought a new one and replaced it. After about a month I had the same problem. It worked only on high. I had it like this for about a month when I lost the blower completely. Went to my mechanic again and he took out the motor, at which time we turned it over and out came about a 1/2 cup of water. Water is all over the glove box. Also like other complaints on the windshield the button rubber piece has expanded so what flows through there to the glove box.

35 Blower problem of the 2002 Ford Taurus

Failure Date: 10/15/2008

Every time it rains heavy, I end up with water on the passenger floor. The defrost blower motor has shorted out three times due to this problem. I looked online and found many many complaints from Ford Taurus owners. Due to some kind of defect,water gets in the heating system and ends up on the passenger floor. It also makes the defrost blower motor and resistor go out.