Gas Recirculation Valve (egr Valve) Problems of Ford E-350

Ford E-350 owners have reported 7 problems related to gas recirculation valve (egr valve) (under the engine and engine cooling category). The most recently reported issues are listed below. Also please check out the statistics and reliability analysis of Ford E-350 based on all problems reported for the E-350.

1 Gas Recirculation Valve (egr Valve) problem of the 2005 Ford E-350

Failure Date: 10/17/2014

While drive on highway,vehicle began to lose power when I encountered a hill. It bogged down and struggled to make it to top of hill and lost speed down to 30 mph or less and then died. It would not start right away, but after letting it sit for 15 minutes, it started and had regained power and I drove ti till I got to the nest hill and did the same thing several times till I made it home 3 hours later for a 10 mile trip. I checked online on the vehicle for Ford owners forum and saw that several people encountered this problem before and described it as bogging down and losing power. Some one suggested changing the egr valve which I had done, and the fuel filters as well as air filter. When I removed the bottom fuel filter under the van, I captured the fuel in the filter and line and it had what looked like silver paint. I kept the sample and it is soft and pliable. I assumed it was a protective coating lining the fuel tank. I don't believe this should be happening,because it could do damage to the injectors and other things.

See all problems of the 2005 Ford E-350 🔎.

2 Gas Recirculation Valve (egr Valve) problem of the 2004 Ford E-350

Failure Date: 10/01/2013

The contact owns a 2004 Ford E-350. The contact stated that while driving approximately 55 mph, he noticed smoke coming from the exhaust pipe. The vehicle was taken to the dealer and to an independent mechanic for diagnosis. Both technicians advised the contact that the egr cooler and the head gasket would have to be replaced. The vehicle was not repaired. The approximate failure mileage was 83,000.

See all problems of the 2004 Ford E-350 🔎.

3 Gas Recirculation Valve (egr Valve) problem of the 2005 Ford E-350

Failure Date: 10/01/2013

Driving uphill on I-70 eastbound by silverthorne, CO the engine simply quit. Limped to side of highway and tried to restart - nothing. Batteries are new, etc just no turning over of the engine. Thoughts are a bad ficm, which there is supposedly a recall but Ford denied that when I called this morning. Had the vehicle towed to a shop in arvada, CO for diagnosis and repairs. Sounds like the egr system is about to go, the ficm is shot and wiring harness for computer is gone - all things Ford is aware of but adamantly refuses to do anything about. This leaves the consumer in the position to have to spend thousands of $'s to repair their design flaws.

4 Gas Recirculation Valve (egr Valve) problem of the 2005 Ford E-350

Failure Date: 08/31/2012

The contact owns a 2005 Ford e350 super duty. The contact stated that he would have to wait hours for the engine to cool down before the vehicle could be started. The vehicle was taken to a dealer for diagnosis and the contact was informed that the engine oil cooler, injectors and the egr cooler would all need to be replaced. The vehicle was taken to an independent mechanic and was repaired. The manufacturer was notified but offered no assistance. The VIN was unavailable. The failure and current mileage was 79,000.

5 Gas Recirculation Valve (egr Valve) problem of the 2006 Ford E-350

Failure Date: 08/12/2011

The contact owns a 2006 Ford f-350. The contact stated that the egr valves malfunctioned and as a result, radiator fluid leaked into the motor. The vehicle was taken to the dealer who diagnosed that the egr valve and oil cooler needed to be replaced. The manufacturer was made aware of the failure who did not offer any assistance. The vehicle was repaired. The failure mileage was 95,000 and the current mileage was 117,000.

See all problems of the 2006 Ford E-350 🔎.

6 Gas Recirculation Valve (egr Valve) problem of the 2004 Ford E-350

Failure Date: 04/25/2005

2004 Ford e-450 ambulance 5/31/06 crew stated the engine was surging, egr valve replaced by dealership. 5/31/06 crew stated a/c quit blowing and grinding noise heard larger fuse installed by dealership. Dealership stated all other a/c test checked out ok. Dealership added booster replaced to diesel fuel also replaced filter, drained water separator. 9/1/06 engine oil leaking, crew also had a/c concerns again dealership replaced Geo rotor oil pump cover gasket and seal wear sleeve and reassemble post road. Dealership found compressor shaft broke replaced a/c compressor and clutch assemble accumulator and front orifice tube. Dealership also replaced fuel injector control module harness, and exhaust pressure sensor secondary to recall. 10/12/05 crew complains that engine sound like it is "sucking air" dealership stated nothing wrong, later that week crew members found air leak at turbo bracket contacted dealership they advised that nothing was wrong and that was the way it should sound. We still have this extreme surging sound in the cab on acceleration, the sound is so loud that we can not hear the communication radio. This truck is a 2004 ambulance with only 24,964 miles on it and is housed inside a climate controlled station. We are again making an appointment to have turbo check because of air leak.

7 Gas Recirculation Valve (egr Valve) problem of the 2003 Ford E-350

Failure Date: 05/06/2003

The consumer was driving on the highway preparing to exit when there was a loud "pop" and the engine stalled. The consumer coasted to the side of the road and noticed smoke emitting from under the hood. When the hood was opened, the vehicle exploded and caused 2nd degree burns to the consumer.

See all problems of the 2003 Ford E-350 🔎.